XTL/XTLN/XTLN-WiFi Panels:
The Device Setup window allows you to define the XTL/XTLN/XTLN-WiFi panel configuration. You can
install and address up to four wireless keypads.
Device Number: Enter the address number of the wireless keypad you are programming. The valid
range is 2-5.
Device Name: Enter the name you wish to assign to the wireless keypad. The name may be up to 16
characters long. If no name is entered, *UNUSED* is displayed.
To remove a keypad from the system, delete the device name by leaving this option blank.
Note: Do not remove the keypad if it is currently in use.
Serial Number: This option only displays when a device number is entered above. Enter the eight-
digit serial number found on the wireless keypad.
Supervision Time: Select the supervision time required for the wireless keypad. The wireless keypad
must check-in at least once during this time or a missing condition is indicated for that device. Select
60 or 240 minutes. Select None for unsupervised operation. Default is 240 minutes.