XR500 Series Canadian Programming Guide Digital Monitoring Products
19
DEVICE SETUP
6.13
OVERRIDE NO YES
Schedule Override
UsethisoptiontoallowdoorON/OFFschedulestobeoverriddenbythearmed
condition of the system. Selecting YES causes the on time for a door schedule to be
ignored when all areas assigned to Access Areas for this device are armed. Should
any area become disarmed after the door schedule on time, the device output turns
on. A door output which is on during a disarmed period automatically turns off when
all access areas assigned to the device become armed, even if the scheduled off
time has not been reached. This feature can be used to keep doors locked when a
factory opens late, or is forced to close early, due to a snow storm or other cause.
Select NO to allow door schedules to operate independent of system armed status.
Note: When OVERRIDE is YES and there are no areas programmed in ACCESS AREAS,
the door schedule for that device does not work. Either set OVERRIDE to NO or
enter an area number in ACCESS AREAS.
6.13 Auto Force Arm Device?
Select YES to have all Display Areas assigned to this keypad automatically arm and
force arm faulted zones at arming. The user is not prompted to select areas to
arm or force arm faulted zones after choosing ARM at the keypad. If Closing Code
is programmed as YES, only the matching areas between the Display Areas and
the User Code’s authorized areas arm. Also, when YES is selected, the user is not
prompted to select areas to disarm after entering a code at Entry Delay or after
choosing Disarm at the keypad. All matching areas assigned to the User Code and to
this keypad are automatically disarmed. When NO is selected, the user is prompted
toselectareas(ALLNOYES)andchoosetoforcearmorbypassatarmingand
disarming. Default is NO.
6.15 Door Real-Time Status?
Select YES tohavereal-timedoorstatusmessagessenttoPCLogreportingandEntré
reporting for this device. Messages are sent anytime the panel turns the door relay on or
off. Default is NO.
6.16 Send Door Forced Message?
Select YES tohavethepanelsendareal-timedoorstatusmessageofForcedOpen(FO)
toPCLogreportingandEntréreportingwhenthedoorrelayisoff,butthedoorzonehas
transitioned from its normal state. Default is NO.
6.17 Program 734/734N Options
Select YES toprograma734/734N/
734N-WiFi
Wiegand Interface Module. The options
displayedfora734ora734Narethesame.
Toprograma734,theDevicetypemustbesettoDOORandtheDeviceCommunication
Type must be set to KPD BUS.
Toprogramthe734N/
734N-WiFi
, the Device Type must be set to DOOR and the Device
Communication Type must be set to NETWORK.
6.18.1 Activate Zone 2 Bypass
Select YES to activate the Bypass option.
Selecting NO allows standard zone operation on Zone 2 and displays the ACTIVATE
ZONE 3 REX option. Default setting is NO.
Ifthedoorbeingreleasedbythe734/734N
/
734N-WiFi
moduleisprotected(contact
installed),youcanprovideaprogrammableBypassentry/exittimerbyconnecting
itscontactwiringtothe734/734N
/
734N-WiFi
moduleZone2.Whentheon-board
Form C relay activates and the user opens the door connected to Zone 2, the zone is
bypassed for the number of seconds programmed in ZONE 2 BYPASS TIME allowing the
usertoenter/exit.
IfZone2doesnotrestore(doorclosed)withintheprogrammedtimeminusten
seconds,the734/734N
/
734N-WiFi
piezo pulses during the last ten seconds. If Zone
2 restores prior to the end of the programmed time, the piezo silences. If the zone
doesnotrestorebeforetheprogrammedtime,the734/734N
/
734N-WiFi
ends the
bypass and indicates the open or short zone condition to the panel.
6.18.2
ZONE 2 BYPASS
TIME: 40
Zone 2 Bypass Time
Enter the number of Bypass seconds to elapse before the Bypass timer expires.
Range is from 20 to 250 seconds. Press any top row select key to enter the number
ofseconds.Ifthedoorremainsopenwhenthetimerexpiresazoneopen/shortis
sent to the panel for Zone 2. The default is 40 seconds.
AUTO FORCE ARM
DEVICE? NO YES
DOOR REAL-TIME
STATUS? NO YES
SEND DOOR FORCED
MESSAGE? NO YES
PROGRAM 734
OPTIONS? NO YES
ACTIVATE ZONE 2
BYPASS? NO YES