XR500 Series Canadian Programming Guide Digital Monitoring Products
61
STOP
SET LOCKOUT CODE
Stop
20.1
STOP
Stop
Save Programming
WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN
AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE
PROGRAMMING CHANGES.
At the STOP prompt, pressing any Select key allows you to exit the Programmer
function of the panel. When selected, the panel performs an internal reset and
exits the programmer.
The STOP routine causes the following conditions to occur:
• All1100SeriesDMPWirelesstransmittersareresettoNORMAL
• ThepanelStatusListiscleared
During the reset, all keypad displays are momentarily blank for two seconds. After
the reset, the programming function terminates and the keypads return to the status
list display.
The STOP prompt does not disarm the system. Any new areas or zones that were
added during programming are not armed until the system is disarmed and armed
again.
Missing LX-Bus™ Modules Displayed
The Programmer includes a feature following the STOP routine that displays the
nameofanyprogrammedLX-Busmodulenotcurrentlyconnectedtothepanel.For
example,ifyouhadenabledanyLX-Busoptionsandnotyetinstalleda481LX-Bus
ExpansionCard,aftertheSTOProutinethepaneldisplaysNOLXBUSCARD.Thisisa
helpful reminder to install the card. This feature can also be a troubleshooting tool
to indicate a problem if you installed the card and this message still displays. The
followinglistshowsthedifferentmessagesandtheirassociatedLX-Buscards.
Keypad Display Missing Card
NO LXBUS CARD 481LX-Bus™ExpansionCard
NO PRINTER CARD 462PPrinterInterfaceCard
NO HOST CARD 462NNetworkInterfaceCard
(withNETWORKcommunicationselected)
The above messages clear automatically from the keypad after a few moments.
Power Up
When the XR500 Series Canadian panel is powered up after an AC power failure,
any zone transitions are not recognized for 120 seconds. Normal zone processing
resumes at the end of the 120 seconds.
Set Lockout Code
21.1
SET LOCKOUT CODE
Set Lockout Code
PressingCOMMANDattheSTOPpromptdisplaysSETLOCKOUTCODE.Thisallows
you to program a code that is then required to gain access to the panel internal
Programmer through the keypad. You can change this code at any time to any
combinationofnumbersfromthreetovedigitslong.Youdonotneedtoenter
leading zeros when using the lockout code. Initializing the panel does not clear a
LockoutCode.LockoutCodescanbechangedthroughRemoteLink.
Once you have changed the code, it is important to write it down somewhere and
storeitinasafeplace.LostLockoutCodesrequirethepaneltobesentbackto
DMPforrepair.YoumaycancelaLockoutCodebyentering00000attheSetLockout
Code command.
Lockout Code restriction
DonotsetaLockoutCodehigherthan65535.