Digital Monitoring Products XR500 Series Canadian Programming Guide
32
SYSTEM OPTIONS
9.27
PANIC SUPERVISION:
NO YES
Panic Supervision
SelectYEStoenablea30daysupervisionoftheModel1145-1-B-PSVkeyfob.
Default is NO.
Thisoptionallowsakeyfobthatislostorhasadeadbatterytobeidentiedatthe
Central Station host automation system as a missing transmitter, without the need to
applyasupervisiontimeinzoneinformationprogramming.SCS-VRVersion1.3.6orhigher
isrequiredtoreceive1145-1-B-PSVsupervisionmessagesthroughtheXR500panel.
The1145-1-B-PSVkeyfobsupervisionmessageiscommunicatedtoSCS-VRusingall
XR500 communication paths where Panic Test is YES within Advanced Communication
programming.AsupervisionmessageisautomaticallysentfromthekeyfobtoSVS-VR
every four hours, resetting the 30 day countdown timer for that key fob serial number.
Ifthe30daytimerexpiresforakeyfobserialnumber,SCS-VRwillgenerateazone
missing message to the host automation system. For the application where the key fob is
programmed into several XR500 Version 210 or higher panels, a supervision message sent
through any XR500 into which the key fob is programmed will satisfy the 30 day timer.
TheSCS-VRzonemissingmessagetohostautomationwillbeforthelastpanelaccount
numberwherethekeyfobsuccessfullycommunicatedasupervisionmessagetoSCS-VR.
ThekeyfobMISSINGisnotdisplayedorrecordedattheXR500controlpanel.
Inaddition,thisoptionallowsformanualtestingof1145-1-B-PSVkeyfobsduringWalk
Test(8144)orPanicTestfromtheusermenu.Akeyfobthatissuccessfullyactivated
during these test modes will cause an increment to the keypad display TRIPS counter and
aVerifymessageissenttoSCS-VRforthatzone.Forthose1145-1-B-PSVkeyfobsthat
are programmed into the panel but not manually tested, a Fail message is NOT displayed
atthekeypadandisnotsenttoSCS-VR.