Digital Monitoring Products XR500 Series Canadian Programming Guide
38
OUTPUT GROUPS
Output Groups
13.1
OUTPUT GROUPS
Output Groups
This function allows you to assign outputs to groups. Output groups can be assigned
to other areas of programming such as Output Options or Alarm Action of Zone
Information, just like single outputs are assigned. This allows the entire group of
outputs to turn on and off as required by the programming option.
13.2
GROUP NO: -
Group Number
Enter a group number from 1 to 20. Up to 20 different groups may be assigned.
13.3
GROUP NAME X X
Group Name
The group name displays. To change the default name, press any top row Select key
then enter up to 32 characters for the group name. Press COMMAND to enter the
outputs to be assigned to the group.
13.4
OUTPUT NO 1: 0
OUTPUT NO 2: 0
OUTPUT NO 4: 0
OUTPUT NO 5: 0
OUTPUT NO 3: 0
OUTPUT NO 7: 0
OUTPUT NO 8: 0
OUTPUT NO 6: 0
Output Number
EntertheOutputnumber.Entryrangeis1to6,450to474,480to499,500to999
(outputs),D1toD16(doors),andG1toG20(groups).Themaximumnumberof
outputsthatcanbeassignedtoaspecicgroupiseight.
An output group may be assigned as one of the output numbers in another output
group.
Example:OutputGroup1consistsofonlyfourassignedoutputs.OutputGroup
1couldbeassignedasoneoutputinOutputGroup2.OutputGroup2couldstill
have7otheroutputsassignedtothatgroup.WhenOutputGroup2isturnedon,11
outputscouldbeturnedon.ThisallowsOutputGroupstobeassignedwithinother
OutputGroupsprovidingmanycombinations.
Outputgroups1to10canbeassignedbyauserproleforapplicationssuchas
elevatorcontrol.SeetheXR500User’sGuide(LT-0683CAN)OutputGroupsectionfor
additional information.
Outputgroups11to20cannotbeassignedtoaproleandareavailablefor
installation applications such as special lighting, etc. To assign these groups to a
prole,useRemoteLink™orSystemLink™softwarefromDMP.
Comentarios a estos manuales