Digital Monitoring Products XR500 Series Canadian Programming Guide
24
REMOTE OPTIONS
7.11.2 Encrypt Cellular Remote
YES encrypts data sent over a cellular connection. Default is NO.
7.12 Allow RS-232 Remote
YESallowsremoteprogrammingovertheon-boardRS-232port.DefaultisYES.
7.13 Entré Connection
This option displays only if the panel has network capability. Select NET to allow
adedicatednetworkconnectionwithEntré.OptionsareNONEorNET.Defaultis
NONE.
7.13.1 Entré Incoming TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheincomingEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestoandfromtheEntrésoftware.
This port cannot be the same port as programmed in Network Programming Port.
The default Programming Port setting is 2011.
7.13.2 Entré IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheEntré
IPaddresswherethepanelsendsnetworkmessages.TheEntréIPAddressmustbe
unique and cannot be duplicated on the network. Enter all 12 digits and leave out
theperiods.Forexample,enterIPaddress192.168.0.250as192168000250.The
periods display automatically. Default is 0.0.0.0
7.13.3 Entré Outbound TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheoutboundEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestotheEntrésoftware.Defaultis
2001.
7.13.4 Entré Backup IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheIP
backupaddresswherethepanelsendsnetworkmessagesiftherstEntréIPAddress
fails.TheEntréIPAddressmustbeuniqueandcannotbeduplicatedonthenetwork.
Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250as192168000250.Theperiodsdisplayautomatically.Defaultis
0.0.0.0
7.13.5 Entré Backup TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
backupprogrammingportnumberfortheoutboundEntréconnectionincasethe
connection to the primary IP fails. Default is 2001.
7.13.6 Entré Checkin
Selecttherateatwhichcheck-inmessagesaresentovertheEntréconnection.
Select0(zero)todisablecheckinmessages.Rangeis0,3-240minutes.
Default is 0.
7.13.7 Entré Passphrase
Toenableencryptionenteran8to16-characterPassphraseusingalphanumeric
characters.IfyouleavethePassphraseblank,thepanelcommunicateswithEntré,
but the data is not encrypted. The Passphrase is blank by default.
7.14 Send Local Changes
ThisoptionallowsthepaneltoautomaticallyupdateRemoteLinkatthecentral
station with any changes made to the panel.
Select NET or DD to send local programming changes or User Menu changes to user
codes,userproles,schedules,orholidaydatestoRemoteLinkafterexitingthe
programming or User Menu. If NET is selected, changes are sent using Network. If
DD is selected, changes are sent using Dialer. Default is NO to disable this feature.
ENCRYPT CELL
REMOTE? NO YES
ALLOW 232
REMOTE? NO YES
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
000.000.000.000
ENTRE IP
CHANGES? NO
NO NET DD
SEND LOCAL
SEND LOCAL
000.000.000.000
ENTRE BACKUP IP:
ENTRE BACKUP TCP
PORT: 2001
ENTRE CHECKIN
MINUTES: 0
ENTRE PASSPHRASE
-
ENTRE OUTBOUND
TCP PORT: 2001