Digital Monitoring Products XR500 Series Canadian Programming Guide
24
REMOTE OPTIONS
7.11.2 Encrypt Cellular Remote
YES encrypts data sent over a cellular connection. Default is NO.
7.12 Allow RS-232 Remote
YESallowsremoteprogrammingovertheon-boardRS-232port.DefaultisYES.
7.13 Entré Connection
This option displays only if the panel has network capability. Select NET to allow
adedicatednetworkconnectionwithEntré.OptionsareNONEorNET.Defaultis
NONE.
7.13.1 Entré Incoming TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheincomingEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestoandfromtheEntrésoftware.
This port cannot be the same port as programmed in Network Programming Port.
The default Programming Port setting is 2011.
7.13.2 Entré IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheEntré
IPaddresswherethepanelsendsnetworkmessages.TheEntréIPAddressmustbe
unique and cannot be duplicated on the network. Enter all 12 digits and leave out
theperiods.Forexample,enterIPaddress192.168.0.250as192168000250.The
periods display automatically. Default is 0.0.0.0
7.13.3 Entré Outbound TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheoutboundEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestotheEntrésoftware.Defaultis
2001.
7.13.4 Entré Backup IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheIP
backupaddresswherethepanelsendsnetworkmessagesiftherstEntréIPAddress
fails.TheEntréIPAddressmustbeuniqueandcannotbeduplicatedonthenetwork.
Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250as192168000250.Theperiodsdisplayautomatically.Defaultis
0.0.0.0
7.13.5 Entré Backup TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
backupprogrammingportnumberfortheoutboundEntréconnectionincasethe
connection to the primary IP fails. Default is 2001.
7.13.6 Entré Checkin
Selecttherateatwhichcheck-inmessagesaresentovertheEntréconnection.
Select0(zero)todisablecheckinmessages.Rangeis0,3-240minutes.
Default is 0.
7.13.7 Entré Passphrase
Toenableencryptionenteran8to16-characterPassphraseusingalphanumeric
characters.IfyouleavethePassphraseblank,thepanelcommunicateswithEntré,
but the data is not encrypted. The Passphrase is blank by default.
7.14 Send Local Changes
ThisoptionallowsthepaneltoautomaticallyupdateRemoteLinkatthecentral
station with any changes made to the panel.
Select NET or DD to send local programming changes or User Menu changes to user
codes,userproles,schedules,orholidaydatestoRemoteLinkafterexitingthe
programming or User Menu. If NET is selected, changes are sent using Network. If
DD is selected, changes are sent using Dialer. Default is NO to disable this feature.
ENCRYPT CELL
REMOTE? NO YES
ALLOW 232
REMOTE? NO YES
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
000.000.000.000
ENTRE IP
CHANGES? NO
NO NET DD
SEND LOCAL
SEND LOCAL
000.000.000.000
ENTRE BACKUP IP:
ENTRE BACKUP TCP
PORT: 2001
ENTRE CHECKIN
MINUTES: 0
ENTRE PASSPHRASE
-
ENTRE OUTBOUND
TCP PORT: 2001