Digital Monitoring Products XR500 Series Canadian Programming Guide
20
DEVICE SETUP
6.18.3
RELOCK ON ZONE 2
CHANGE? NO YES
Relock on Zone 2 Change?
Selecting NO leaves the relay on for the door access time when Zone 2 restores.
SelectingYESturnsthe734/734N
/
734N-WiFi
relay off and relocks the door when
Zone 2 changes state. The default is NO.
6.18.4
ACTIVATE ZONE 3
REX? NO YES
Activate Zone 3 Request to Exit
SelectingYESactivatestheZone3RequesttoExit(REX)option.
Selecting NO allows standard zone operation on Zone 3 and displays the ACTIVATE
ONBOARD SPEAKER option. Default setting is NO.
OptionallyconnectaPIR(orothermotionsensingdevice)oramechanicalswitchto
Zone 3 to provide REX capability to the system. When Zone 3 shorts,theon-board
Form C relay activates for the programmed number of seconds. During this time,
theusercanopentheprotecteddoortostarttheprogrammedBypassentry/exit
timer. After the programmed number of seconds, the relay restores the door to its
locked state.
The734/734N
/
734N-WiFi
moduleprovidesabypass-onlyoptionforREXonZone3.
WhenZone3opensfromanormalstate,onlyaBypassoccurs:theon-boardrelay
doesnotactivate.Thisbypass-onlyoptionusestwomethodsofREX.TherstREX
deviceprovidestheprogrammedBypassentry/exittimer.ThesecondREXdevice,or
manual device such as a door knob, unlocks the door.
Anexampleofthebypass-onlycongurationisadoortoanofcethatislocked24
hours a day. Users pass a REX motion detector positioned by the door to begin the
programmed exit timer. Within the programmed number of seconds the user must
then manually activate a second device, such as a REX device or manual door knob,
to unlock the door. If the door is opened after the programmed number of seconds,
the zone goes into alarm
.
6.18.5
ZN 3 REX STRIKE
TIME: 5
Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. Range is from 5 to 250 seconds. Press
any top row select key to enter the number of seconds. The default is 5 seconds.
Press the COMMAND key to move forward to the ACTIVATE ONBOARD SPEAKER option.
The Back Arrow returns to ACTIVATE ZONE 3 REX.
6.18.6
ACTIVATE ONBOARD
SPEAKER? NO YES
Activate Onboard Speaker
Select YES to enable the onboard piezo speaker for local annunciation. Select NO to
turn the piezo off for all operations. This does not affect remote annunciator open
collector(RA)operation.ThedefaultisNO.
6.18.7
CARD OPTIONS:
DMP
Card Options
Press any top row Select key to display options. Press the select key under DMP,
CUSTOMorANYtoselectthatoption.SelectDMPtoindicatethereadersendsa26-
bit DMP data string. Press the COMMAND key to display REQUIRE SITE CODE.
Note: When set to DMP, the 734/734N/734N-WiFi converts 17 bits of the 26-bit
data string into a 5-digit number.
SelectCUSTOMifusinganon-DMPcardorusercodelengthof6to10digits.
Default is DMP.
Select ANY to allow all card reads to activate the door strike relay. The door strike
relay is activated for the length of time programmed in ZN 3 REX STRIKE TIME. No
user code information is sent to the panel.
6.18.8
WIEGAND CODE
LENGTH: 26
CustomCardDenitions
Wiegand Code Length
When using a custom credential, enter the total number of bits to be received in
Wiegand code including parity bits.
PressanytoprowSelectkeytoenteranumberbetween1-255toequalthenumber
ofbits.Defaultis26bits.
Typically,anaccesscardcontainsdatabitsforasitecode,ausercode,andstart/
stop/paritybits.Thestartingpositionlocationandcodelengthmustbedetermined
andprogrammedintothe734/734N
/
734N-WiFi
Module.
CARD OPTIONS:
DMP CUSTOM ANY