Digital Monitoring Products XR500 Series Canadian Programming Guide
56
ZONE INFORMATION
ARM AREAS: PERIM
InanAll/PerimeterorHome/Sleep/Awaysystem,thisspeciestheareatobe
armedbytheKeyFobbuttonbeingprogrammed.ForAll/Perimetersystems,
choosePERIMorALL,forHome/Sleep/AwayorHome/Awaysystems,choose
HOME,SLEEP,orAWAY.
Note:Areas3andhigherinanAll/Perimetersystem,andareas4andhigherina
Home/Sleep/Awaysystemarenotavailableforuse.
Afterselectingtheareas,forone-buttonkeyfobstheZoneNo.:prompt
displays.Fortwo-buttonorfour-buttonkeyfobs,theKeyFobButtonSelection
option displays to program additional buttons.
19.11.10
OUTPUT NO: XXX
Output Number
YoucanspecifyarelayoutputtooperatewhenOUT(Output),PN(Panic),PN2
(Panic2),EM(Emergency),orEM2(Emergency2)isselectedforakeyfob
ButtonActionandthebuttonispressed.Validrangeis1to6,500to999,
D1toD16,orG1toG20.ForanoutputturnedonbyaPN,PN2,EM,orEM2
button action, the output turns off when any area is disarmed.
To enter an output number, press a top row Select key followed by the output
number. Press the COMMAND key.
19.11.11
OUTPUT ACTION:
yyy: XXXXXXXX
Output Action
Thisoptionallowsyoutodenetheoutputaction(STD,PLS,MOM,TGL,OFF)
for the selected output number. The default is Steady.
yyy=thenameofthebuttonbeingprogrammed(TOP,BTM,LFT,RGT).
xxxxxxxx=thecurrentlydenedoutputaction.
OUTPUT ACTION?
STD PLS MOM TGL
STD (Steady) - The output is turned on and remains on.
PLS (Pulse) - The output alternates one second on and one second off.
ThepulsingrateforaModel716relayattachedtotheLX-Busis1.6seconds.
Note:PulseisnotavailableforkeyfobbuttonoutputprogrammedD1toD16or
G1toG20.
MOM (Momentary) - The output is turned on only once for one second.
TGL (Toggle) - The output alternates between the on state and off state. Each
button press toggles the output state.
Note:ToggleisnotavailableforkeyfobbuttonoutputprogrammedG1toG20.
OUTPUT ACTION?
OFF
OFF (Off) - The output is turned off. If programmed, the output was turned
on by some other means such as another button press, a zone action, or a
schedule.
Note:WhentheoutputisassignedtoPN/PN2orEM/EM2buttonactionandis
turned on, the output turns off when any area is disarmed.
When the output action is steady, pulse or toggle and the output is turned on,
the output remains on until:
— the output cutoff time expires
— the output is reset from the keypad menu
— toggled off
19.11.12
NEXT ZONE NO YES
Next Zone
SelectYEStoreturntotheZONENO:-prompttoprogramanewzone.Select
NO to display the Alarm Action option.
Note: All wireless programming is stored in the XR500 Series Canadian panel. The 1100X Wireless
Receiver obtains the necessary programming information from the panel each time the receiver powers up,
when the programmer STOP routine is selected or the panel is reset. The receiver memory refresh takes
upto10secondstocompletedependingonthenumberofwirelesszonesprogrammedandtheRedLED
remains on during this time. Normal receiver operation is inhibited during the memory refresh period.